34 research outputs found

    Towards 3D printed multifunctional immobilization for proton therapy: initial materials characterization

    Get PDF
    Purpose: 3D printing technology is investigated for the purpose of patient immobilization during proton therapy. It potentially enables a merge of patient immobilization, bolus range shifting, and other functions into one single patient-speci c structure. In this rst step, a set of 3D printed materials is characterized in detail, in terms of structural and radiological properties, elemental composition, directional dependence, and structural changes induced by radiation damage. These data will serve as inputs for the design of 3D printed immobilization structure prototypes. Methods: Using four di erent 3D printing techniques, in total eight materials were subjected to testing. Samples with a nominal dimension of 20×20×80 mm3 were 3D printed. The geometrical printing accuracy of each test sample was measured with a dial gage. To assess the mechanical response of the samples, standardized compression tests were performed to determine the Young’s modulus. To investigate the e ect of radiation on the mechanical response, the mechanical tests were performed both prior and after the administration of clinically relevant dose levels (70 Gy), multiplied with a safety factor of 1.4. Dual energy computed tomography (DECT) methods were used to calculate the relative electron density to water ρe, the e ective atomic number Ze , and the proton stopping power ratio (SPR) to water SPR. In order to validate the DECT based calculation of radiological properties, beam measurements were performed on the 3D printed samples as well. Photon irradiations were performed to measure the photon linear attenuation coe cients, while proton irradiations were performed to measure the proton range shift of the samples. The direc- tional dependence of these properties was investigated by performing the irradiations for di erent orientations of the samples. Results: The printed test objects showed reduced geometric printing accuracy for 2 materials (deviation > 0.25 mm). Compression tests yielded Young’s moduli ranging from 0.6 to 2940 MPa. No deterioration in the mechanical response was observed after exposure of the samples to 100 Gy in a therapeutic MV photon beam. The DECT-based characterization yielded Ze ranging from 5.91 to 10.43. The SPR and ρe both ranged from 0.6 to 1.22. The measured photon attenuation coe cients at clinical energies scaled linearly with ρe. Good agreement was seen between the DECT estimated SPR and the measured range shift, except for the higher Ze . As opposed to the photon attenuation, the proton range shifting appeared to be printing orientation dependent for certain materials. Conclusions: In this study, the rst step toward 3D printed, multifunctional immobilization was performed, by going through a candidate clinical work ow for the rst time: from the material printing to DECT characterization with a veri cation through beam measurements. Besides a proof of concept for beam modi cation, the mechanical response of printed materials was also investigated to assess their capabilities for positioning functionality. For the studied set of printing techniques and materials, a wide variety of mechanical and radiological properties can be selected from for the intended purpose. Moreover the elaborated hybrid DECT methods aid in performing in-house quality assurance of 3D printed components, as these methods enable the estimation of the radiological properties relevant for use in radiation therapy

    A dosimetric comparison of real-time adaptive and non-adaptive radiotherapy: A multi-institutional study encompassing robotic, gimbaled, multileaf collimator and couch tracking

    Get PDF
    AbstractPurposeA study of real-time adaptive radiotherapy systems was performed to test the hypothesis that, across delivery systems and institutions, the dosimetric accuracy is improved with adaptive treatments over non-adaptive radiotherapy in the presence of patient-measured tumor motion.Methods and materialsTen institutions with robotic(2), gimbaled(2), MLC(4) or couch tracking(2) used common materials including CT and structure sets, motion traces and planning protocols to create a lung and a prostate plan. For each motion trace, the plan was delivered twice to a moving dosimeter; with and without real-time adaptation. Each measurement was compared to a static measurement and the percentage of failed points for γ-tests recorded.ResultsFor all lung traces all measurement sets show improved dose accuracy with a mean 2%/2mm γ-fail rate of 1.6% with adaptation and 15.2% without adaptation (p<0.001). For all prostate the mean 2%/2mm γ-fail rate was 1.4% with adaptation and 17.3% without adaptation (p<0.001). The difference between the four systems was small with an average 2%/2mm γ-fail rate of <3% for all systems with adaptation for lung and prostate.ConclusionsThe investigated systems all accounted for realistic tumor motion accurately and performed to a similar high standard, with real-time adaptation significantly outperforming non-adaptive delivery methods

    Initial characterization, dosimetric benchmark and performance validation of Dynamic Wave Arc

    Get PDF
    Background: Dynamic Wave Arc (DWA) is a clinical approach designed to maximize the versatility of Vero SBRT system by synchronizing the gantry-ring noncoplanar movement with D-MLC optimization. The purpose of this study was to verify the delivery accuracy of DWA approach and to evaluate the potential dosimetric benefits. Methods: DWA is an extended form of VMAT with a continuous varying ring position. The main difference in the optimization modules of VMAT and DWA is during the angular spacing, where the DWA algorithm does not consider the gantry spacing, but only the Euclidian norm of the ring and gantry angle. A preclinical version of RayStation v4.6 (RaySearch Laboratories, Sweden) was used to create patient specific wave arc trajectories for 31 patients with various anatomical tumor regions (prostate, oligometatstatic cases, centrally-located non-small cell lung cancer (NSCLC) and locally advanced pancreatic cancer-LAPC). DWA was benchmarked against the current clinical approaches and coplanar VMAT. Each plan was evaluated with regards to dose distribution, modulation complexity (MCS), monitor units and treatment time efficiency. The delivery accuracy was evaluated using a 2D diode array that takes in consideration the multi-dimensionality of DWA during dose reconstruction. Results: In centrally-located NSCLC cases, DWA improved the low dose spillage with 20 %, while the target coverage was increased with 17 % compared to 3D CRT. The structures that significantly benefited from using DWA were proximal bronchus and esophagus, with the maximal dose being reduced by 17 % and 24 %, respectively. For prostate and LAPC, neither technique seemed clearly superior to the other; however, DWA reduced with more than 65 % of the delivery time over IMRT. A steeper dose gradient outside the target was observed for all treatment sites (p < 0.01) with DWA. Except the oligometastatic cases, where the DWA-MCSs indicate a higher modulation, both DWA and VMAT modalities provide plans of similar complexity. The average γ (3 % /3 mm) passing rate for DWA plans was 99.2 ± 1 % (range from 96.8 to 100 %). Conclusions: DWA proven to be a fully functional treatment technique, allowing additional flexibility in dose shaping, while preserving dosimetrically robust delivery and treatment times comparable with coplanar VMAT

    Patterns and universals of mate poaching across 53 nations : the effects of sex, culture, and personality on romantically attracting another person’s partner

    Get PDF
    As part of the International Sexuality Description Project, 16,954 participants from 53 nations were administered an anonymous survey about experiences with romantic attraction. Mate poaching--romantically attracting someone who is already in a relationship--was most common in Southern Europe, South America, Western Europe, and Eastern Europe and was relatively infrequent in Africa, South/Southeast Asia, and East Asia. Evolutionary and social-role hypotheses received empirical support. Men were more likely than women to report having made and succumbed to short-term poaching across all regions, but differences between men and women were often smaller in more gender-egalitarian regions. People who try to steal another's mate possess similar personality traits across all regions, as do those who frequently receive and succumb to the poaching attempts by others. The authors conclude that human mate-poaching experiences are universally linked to sex, culture, and the robust influence of personal dispositions.peer-reviewe

    Are men universally more dismissing than women? Gender differences in romantic attachment across 62 cultural regions

    Get PDF
    The authors thank Susan Sprecher (USA), Del Paulhus (Canada), Glenn D. Wilson (England), Qazi Rahman (England), Alois Angleitner (Germany), Angelika Hofhansl (Austria), Tamio Imagawa (Japan), Minoru Wada (Japan), Junichi Taniguchi (Japan), and Yuji Kanemasa (Japan) for helping with data collection and contributing significantly to the samples used in this study.Gender differences in the dismissing form of adult romantic attachment were investigated as part of the International Sexuality Description Project—a survey study of 17,804 people from 62 cultural regions. Contrary to research findings previously reported in Western cultures, we found that men were not significantly more dismissing than women across all cultural regions. Gender differences in dismissing romantic attachment were evident in most cultures, but were typically only small to moderate in magnitude. Looking across cultures, the degree of gender differentiation in dismissing romantic attachment was predictably associated with sociocultural indicators. Generally, these associations supported evolutionary theories of romantic attachment, with smaller gender differences evident in cultures with high–stress and high–fertility reproductive environments. Social role theories of human sexuality received less support in that more progressive sex–role ideologies and national gender equity indexes were not cross–culturally linked as expected to smaller gender differences in dismissing romantic attachment.peer-reviewe

    Volumetric modulated arc therapy of head-and-neck cancer on a fast-rotating O-ring linac: Plan quality and delivery time comparison with a C-arm linac

    No full text
    BACKGROUND AND PURPOSE: Linac improvements in gantry speed, leaf speed and dose rate may increase the time-efficiency of volumetric modulated arc therapy (VMAT) delivery. The plan quality achievable with faster VMAT however remains to be investigated. In this study, a fast-rotating O-ring linac with fast-moving leaves is compared with a C-arm linac in terms of plan quality and delivery time for VMAT of head-and-neck cancer (HNC). MATERIAL AND METHODS: For 30 patients with HNC, treatment planning was performed using dual-arc (HA2) and triple-arc (HA3) VMAT on a Halcyon fast-rotating O-ring linac and using dual-arc VMAT on a TrueBeam C-arm linac (TB2). Target coverage metrics and complication probabilities were compared. Plan delivery was verified using 3%/3 mm gamma-index analysis of helical diode array measurements. Volumetric image acquisition and plan delivery times were compared. RESULTS: All studied VMAT-techniques fulfilled the target coverage objectives. D2% to the boost volume was higher for HA2 (median 103.7%, 1st-3rd quartile [103.5%;104.0%]) and HA3 (103.2% [103.0%;103.7%)] than for TB2 (102.6% [102.3%;103.0%)], resulting in an increased boost target dose heterogeneity for HA2 and HA3. Complication probabilities were comparable between HA2 and TB2, while HA3 showed a xerostomia probability reduction (0.8% [0.2%;1.8%]) and dysphagia probability reduction (1.0% [0.2%;1.8%]) compared with TB2. Gamma-index agreement scores were never below 93.0% for HA2, HA3 and TB2. Volumetric imaging and plan delivery time was shorter for HA2 (1 m 24 s ± 1 s) and HA3 (1 m 54 s ± 1 s) than for TB2 (2 m 47 s ± 1 s). CONCLUSION: For VMAT of HNC, the fast-rotating O-ring linac at least maintains the plan quality of two arcs on a C-arm linac while reducing the image acquisition and plan delivery time.status: publishe

    Progression-directed Therapy for Oligoprogression in Castration-refractory Prostate Cancer.

    No full text
    In metastatic castration-refractory prostate cancer (mCRPC), state-of-the-art treatment consists of androgen biosynthesis inhibition (abiraterone), inhibition of the androgen receptor (enzalutamide), chemotherapy, or radium-223 in combination with androgen deprivation therapy (ADT). A subgroup of these patients show oligoprogression, with the progression of only a limited number of metastatic spots, while all other metastases remain controlled by ongoing systemic therapy. In a bi-institutional retrospective study, we tested the hypothesis that progression-directed therapy (PDT) targeting oligoprogressive lesions might defer the initiation of next-line systemic treatment (NEST). A total of 30 patients were diagnosed with mCRPC and experienced oligoprogression, defined as a total of three or fewer progressive lesions either at known metastatic sites and/or the appearance of new metastasis and/or local recurrence. All patients were under active ADT with or without second-line systemic treatment. All patients received PDT targeting the oligoprogressive lesions, while ongoing systemic treatment was maintained. There was median NEST-free survival of 16mo (95% confidence interval [CI] 10-22) and progression-free survival of 10mo (95% CI 6-15) with only minor radiotherapy- or surgery-related toxicity. These findings encourage further prospective trials. PATIENT SUMMARY: In patients with metastatic castration-refractory prostate cancer, surgical treatment or high-dose radiation therapy directed to only the limited number of progressive metastatic spots, while all other metastases remained controlled by ongoing systemic therapy, led to substantial postponement of next-line systemic treatment in our study.status: Published onlin
    corecore